Thermocouple compensation cable

  • k type thermocouple cable
k type thermocouple cable

k type thermocouple cable

  • k type thermocouple cable
  • k type cable
  • Product description: When choosing k type thermocouple cable|k type cable, you must know the ambient temperature of the thermocouple compensation wire and the on-site industrial and mining conditions.
  • INQUIRY

When choosing k type thermocouple cable|k type cable, you must know the ambient temperature of the thermocouple compensation wire and the on-site industrial and mining conditions. Choose the appropriate compensation wire sheath according to the on-site environment temperature. Generally, choose PVC sheath when the ambient temperature is -25~105℃. When the ambient temperature is -60~205℃, choose polyperfluoroethylene, Teflon, etc. as the sheath of the compensation wire. Therefore, you must pay attention to the on-site industrial and mining situation when choosing. If there is signal interference on site, the cable must also be shielded to resist signal interference.

k type thermocouple cable|k type cable structure

k type thermocouple cable

k type thermocouple cable|k type cable Operational performance

1 .Working Temperature

Max. 200°C for heat resistant cable

Max. -20~70°C&-20~100°C for common cable

2. Min Environment Temperature

Wire & cable with fluoroplastic insulation and sheath:-60°C for fixed installation, -20°C for non-fixed installation;Wire & cable with PVC insulation and sheath:-40°C for fixed installation, -15°C for non-fixed installation

3. Bending radius

It should be not less than 16 times that of cable outer diameter for compensational cable with copper tape shielding.It should be not less than 10 times that of cable outer diameter for compensational cable with other structure.

Type

 Description

KX-GS-VV

Precise grade compensational wire for KType Thermocouple with PVC insulation and sheath for general purpose

KX-GS-VPV

Precise grade compensational wire for KType Thermocouple with PVC insulation and sheath, copper wire braided shielding for general purpose

KX-HS-FF

Precise grade high temperature compensational wire for K Type Thermocouple with Fluoroplastic insulation and sheath for heat resistant purpose

KX-HS-FP1F

Precise grade high temperature compensational wire for K Type Thermocouple with Fluoroplastic insulation and sheath, tinned copper wire braided shielding for heat resistant purpose

KX-HS-FB

Precise grade high temperature compensational wire for KType Thermocouple with F4 insulation and glass wire braided sheath for heat resistant purpose

KX-HS-FBP1

Precise grade high temperature compensational wire for KType Thermocouple with F46 wrapped insulation glass wire braiding, tinned copper wire braided shielding and glass wire braided outer sheath for heat resistant purpose

KX-HS-FP1V105

Precise grade high temperature compensational wire for K Type Thermocouple with Fluoroplastic insulation, tinned copper wire braided shielding, 105°C heat resistant and PVC sheath for heat resistant

k type thermocouple cable|k type cable Note:

1.Compensation wire types, such as KC JX SC EX NC TX etc.  only need to rewrite the first item of the model, like EX-G-VV and TX-H-FVP etc.
2.Suffix "R"is added to the original type for indication of cable with soft multi strand core.eg.TX-G-VVPR
3.We also produce compensational cable with PE(Y)insulation or XLPE(YJ) insulation if needed.
4.Shielding laver material of compensational cable includes metallic tape wrapping such as compound aluminum tape(P3) and compound copper tape(P2)
5.Prefix"ZR-" is added to the original type for indication of flame retardant type compensational cable.
6.Suffix "-22" is added to the original type for indication of compensational cable with steel tape armor,"-32"for that with steel wire armor.
7.Prefix "ia-" is added to the original type for indication of intrinsic safety type compensational cable.

Category, Class mark and Sheath Color of thermocouple compensation Cable and Wire

Name

Pair No. of core

Nominal cross section area(mm2)

Core structure

A

R

Compensational wire

1

0.5

1/0.80

7/0.30

1.0

1/1.13

7/0.43

Compensational cable

1~19

1.5

1/1.37

7/0.52

2.5

1/1.76

19/0.41

k type thermocouple cable|k type cable Main Technical Requirement

Type

Compensational wire & cable core

Compensation wire insulation layer coloringInsulation color of compensational wire

Thermocouple graduation

Positive pole

Negative pole

Positive pole

Negative pole

SC or RC

Cu

0.6 Cu-Ni

Red

Green

S (PtRh10-PT) or R (PtRh 13-PT)

KCA

Fe

22Cu-Ni

Red

Blue

K(NiCr-NiSi)

KCB

Cu

40Cu-Ni

Red

Blue

KX

l0Ni-Crl0

3Ni-Si

Red

Black

EX

10Ni-Crl0

45Cu-Ni

Red

Brown

E(NiCr-NiSi)

JX

Fe

45Cu-Ni

Red

Violet

J(Fe-CuNi)

TX

Cu

45Cu-Ni

Red

White

T(Cu-CuNi)

The function of the k type thermocouple cable|k type cable is to extend the hot electrode, that is, the cold end of the mobile thermocouple, and connect with the display instrument to form a temperature measurement system. Equivalently adopts the national standard of IEC 584-3 "Thermocouple Part III-Compensation Wire". The products are mainly used in various temperature measuring devices and have been widely used in nuclear power, petroleum, chemical, metallurgy, electric power and other sectors,k type thermocouple cable,k type cable.

close
Scan the qr codeClose
the qr code