Flat cable or ribbon cable is a flat wire formed by a combination of a plurality of wires. Flat ribbon cable is suitable for connection between mobile electrical equipment in harsh environments such as power generation, metallurgy, chemical industry and port.
Flat cable Model and name
Model |
Name |
YVVB |
Flat cable for soft PVC insulation and sheathing |
YFFB |
Flat cable for nitrile-polyethylene composite insulation and sheathing |
YEEB |
Flat cable for thermoplastic elastomer insulation and sheath movement |
YGGB |
Flat cable for silicone rubber insulation and sheath movement |
YVFB |
Polyvinyl chloride insulated thermoplastic elastomer sheathed mobile flat cable |
YVEB |
Polyvinyl chloride insulated thermoplastic elastomer sheathed mobile cable |
YFEB |
Nitrile-polyvinyl chloride composite insulated thermoplastic elastomer sheathed mobile flat cable |
YFGB |
Nitrile-polyvinyl chloride composite insulated silicon rubber sheathed mobile flat cable |
YGFB |
Silicone rubber insulated nitrile polyvinyl chloride composite sheathed mobile flat cable |
YGEB |
Silicone rubber insulated thermoplastic elastomer sheathed flat cable for mobile |
Example
(1) Rated voltage 0 6/1KV soft PVC insulation and sheathed mobile flat
Cable 3 core, 25mm2 is expressed as: YVVB-0 6/1 3 x 25mm2
(2) Flat cable with rated voltage 0 6/1KV for silicone rubber insulation and sheathing, 4
Core, 6mm2 is expressed as: YGG-0 6/1 4 x 6mm2
(3) Rated voltage 0 6/1KV nitrile PVC composite insulated silicone rubber sheath
Flat cable for mobile, 3-core, 35mm2 is expressed as:
YFGB-0 6/1 3 x 35mm2
Flat cable use characteristics
1 cable conductor long-term working temperature: PVC insulation, nitrile PVC insulation, thermoplastic elastomer insulation does not exceed 70 ° C; silicone rubber insulation does not exceed 180 ° C
2 The minimum bending radius of the cable is not less than 6 times the outer diameter of the cable.
3 Ambient temperature of cable operation: PVC insulation not lower than 0 °C, nitrile PVC composite insulation, thermoplastic elastomer insulation not lower than -20 ° C; silicone rubber insulation not lower than -40 ° C
4 Cable moving speed Polyvinyl chloride insulation, nitrile and polyvinyl chloride insulation, thermoplastic elastomer insulation not exceeding 1.5 m / s, silicone rubber insulation not exceeding 1.25 m / s.
Silicone rubber flat cable is the most commonly used in flat cable. You can refer to the introduction of silicone rubber flat cable. If you have any questions, please feel free to contact us.
Contact: Tiankang Export Sales Department
Phone: +86-18226665885
Tel: +86-0550-7788337
Email: sales@tiankangcable.com
Add: No.20# RenHe South Road,TianChang,AnHui Province,China