·Intrinsically safe anti-riot temperature measurement system The thermocouple compensation cable adopts low-inductance and low-capacitance structure. Besides the performance of the above-mentioned thermocouple compensation cable, it also has explosion-proof and safety performance.
Thermocouple compensation cable code and meaning:
Item
Code
Code meaning
Item
Code
Code meaning
model
SC
Use S index number thermocouple compensation wire
Heat resistance rating
70
High operating temperature is 70 ° C
RC
Use R index number thermocouple compensation wire
105
High operating temperature is 105 ° C
NC
Equipped with N-index thermocouple compensation wire
200
High operating temperature is 200 ° C
NX
Equipped with N-index thermocouple compensation wire
250
High operating temperature is 250 ° C
KCA
Use K index number thermocouple compensation wire
Insulation Materials
V
Polyvinyl chloride
KX
Use K index number thermocouple compensation wire
Y
Polyethylene
EX
E-scale thermocouple compensation wire
B
Polypropylene
JX
Use J index number thermocouple compensation wire
F4
PTFE
T
Use T graduation number thermocouple compensation wire
F46
Polychloroethylene propylene
Serial code
ZR
Flame retardant cable
Jacket material
V
Polyvinyl chloride
ia
Intrinsically safe cable
B
glass fiber
Use classification
G
General use
F4
PTFE
H
Heat resistant
F46
Polychloroethylene propylene
Accuracy level
S
Precision level
Shielding material
P
Copper wire weaving
P1
Tinned copper wire weaving
/
Ordinary level
P2
Copper tape wrapping
P3
Aluminum/plastic composite film wrapping
specification
2×conductor cross-sectional area mm2
Conductor type
Single strand conductor can be omitted
R
Stranded conductor
Armoured
22
Steel belt armor
KCB
Contact: Tiankang Export Sales Department
Phone: +86-18226665885
Tel: +86-0550-7788337
Email: sales@tiankangcable.com