Cable and wire technology

Thermocouple compensation wire type and alloy wire material

Thermocouple compensation wire is suitable for temperature control systems of energy, metallurgy, petroleum, chemical and other factories and mines and scientific research departments. It is used for the connection between the cold end of the temperature measuring instrument and the temperature measuring instrument. This introduces the characteristics and uses of the thermocouple compensation wire. This paper introduces the thermocouple compensation wire type and the thermocouple compensation wire alloy wire material with different indexing numbers.

Thermocouple compensation wire Model name: (take K-type thermocouple compensation wire as an example)

Type

Structural materials

KX-VV

Polyvinyl chloride insulation and sheathing common compensation wire and cable for thermocouples with K index

KX-VV22

Polyvinyl chloride insulated and sheathed steel tape armored compensating cable for ordinary grade K index thermocouple

KX-VPV

Polyvinyl chloride insulated and sheathed copper wire braided shielded conductor wire and cable for common grade K thermocouples

KX-VPV22

PVC insulated and sheathed copper wire braided sub-shield steel strip armored ordinary grade K index thermocouple compensating cable

KX-VVP

Polyvinyl chloride insulated and sheathed copper wire braided general shielded thermocouple compensation cable for ordinary grade K

KX-VV22P

PVC insulated and sheathed copper wire braided general-shield steel strip armored ordinary grade K index thermocouple compensation cable

KX-VPVP

Polyvinyl chloride insulated and sheathed copper wire braided sub-shield and total shielded common-grade K-type thermocouple compensation cable

KX-VPV22

PVC insulated and sheathed copper wire braided sub-shield and total shield steel tape armored ordinary K index thermocouple compensation cable

KX-FF

Fluoroplastics and sheathed compensating wires and cables for thermocouples of ordinary grade K

KX-FPF

Fluoroplastic and sheathed copper wire braided sub-shield shielded wires and cables for common grade K thermocouples

KX-FFP

Fluoroplastic and sheathed copper wire braided general shielded compensating wires and cables for common grade K thermocouples

KX-FPFP

Fluoroplastic and sheathed copper wire braided sub-shield and total shielded thermocouple compensation cable for ordinary grade K index

Thermocouple compensation wire Alloy wire material and insulation color:

Compensation wire type

Equipped with thermocouple

Thermocouple indexing number

Compensation wire alloy wire

Insulation color

 

 

 

Positive level

Negative level

Positive level

Negative level

SC

Platinum rhodium 10-platinum thermocouple

S

SPC (copper)

SNC (copper nickel)

red

green

RC

Platinum and rhodium 13 thermocouple

R

RPC (copper)

RNC (copper nickel)

red

green

KCA

Nickel-chromium-nickel silicon thermocouple

 

 

K

KPCA (iron)

KNCA (copper nickel)

red

blue

KCB

 

 

KPCB (copper)

KNCB (copper nickel)

red

blue

KX

 

 

KPX (nickel chrome)

KNX (nickel silicon)

red

black

NC

Nickel-chromium-silicon-silicon thermocouple

 

N

NPC (iron)

NNC (copper nickel)

red

gray

NX

 

 

NPX (nickel chrome silicon)

NNX (nickel silicon)

red

gray

EX

Nickel-chromium-copper-nickel thermocouple

E

EPX (nickel chrome)

ENX (copper nickel)

red

Brown

JX

Iron-copper nickel thermocouple

J

JPX (iron)

JNX (copper nickel)

red

purple

TX

Copper-copper nickel thermocouple

T

TPX (copper)

TNX (copper nickel)

red

White

Thermocouple compensation wire specification:

sectionmm2

Conductor diametermm

Logarithmic range

Core number range

Special restrictions

0.5

1/0.807/0.30

123,~24

2

Do not armor when the core is 4 pairs or less

0.75

1/0.977/0.37

1.0

1/1.137/0.43

1.5

1/1.387/0.52

2.5

1/1.787/0.68